ST Series Pure Sine Wave Power Inverter User’s Manual e13
2-5. Mechanical drawings NEG(-)REVERSE POLARITY WILL DAMAGE UNITPOWERSTATUSS4S3S2S1LOAD LEVELBREAKERPOS(+)DC INPUTAC INPUT
2-5. Mechanical drawings POS(+) NEG(-)WARNING: REVERSE POLARITY WILL DAMAGE UNITDC INPUTPOWERON-OFF-REMOTEREMOTE PORT0IINPUT LEVEL01
3. Installation 3-1.Where to install The power inverter should be installed in a location that meets the following requirements: 3-1-1. Dr
3-2 Hard-wire Installation AC wiring connections: 3-2-1. The AC wiring compartment is located on the front panel of the ST series. Remove the AC w
3-2-2. Connect AC output and AC input wiring to the ST series terminals. Please take the following information as your reference. Wire length / ga
POWERON-OFF-REMOTEREMOTE PORT0IINPUT LEVEL01AC INPUTBREAKERLOAD LEVELS1S2S3S4POWERSTATUSPOS(+) NEG(-)WARNING: REVERSE POLARITY WILL DAMAGE UNITDC
Model No Wire AWG Inline Fuse ST1000-112 / 212 # 2 150 A ST1000-124 / 224 # 4 80 A ST1000-148 / 248 # 6 40 A ST1500-112 / 212 # 2 200 A ST1
AWG#2 - #6 INLINE FUSEPOS(+)NEG(-) ST-1000 ST-1500 16
PVC WIRE SPRING WASHERM8 NUTWASHERRING TERMINALPLASTIC COVERSPRING WASHERM8 NUTRING TERMINALWASHER
NEG(-)REVERSE POLARITY WILL DAMAGE UNITPOWERSTATUSS4S3S2S1LOAD LEVELBREAKERPOS(+)DC INPUTAC INPUT10INPUT LEVEL0IPORTREMOTE ON-OFF-REMOTEPOWER4. Int
Contents 11. Important Safety Instructions…………………………………………………………………….2 1-1 General safety precautions………………………………………
POS(+) NEG(-)WARNING: REVERSE POLARITY WILL DAMAGE UNITDC INPUTPOWERON-OFF-REMOTEREMOTE PORT0IINPUT LEVEL01AC INPUTBREAKERLOAD
4-2-6. Chassis Ground: Connect the wire # 8 AWG to vehicle chassis. WARNING! Operating the inverter without a proper ground connection may cause ele
4-2-10. AC Frequency:Selected by “S4” Dip Switch Frequency S4 50 HZ OFF 60 HZ ON 4-2-11. Status:Display Power & Fault Status Green LED LED Si
ST1000 ST1500 ST2000 ST2500 S1 S2 S3 DISABLE DISABLE OFF OFF OFF 20W 40W ON OFF OFF 40W 80W OFF ON OFF 50W 100W ON ON OFF 60W 120W OFF OFF ON 8
4-4. Rear Panel Operation 4-4-1. Rear view: 4-4-2. Fan Ventilation: Be sure to keep it a distan
Problems and Symptoms Possible Cause Solutions No AC Power “Output” STATUS illuminates the LED a. Powe
1. Important Safety Instructions WARNING ! Before using the Inverter, read and sav
2. Functional Characteristics 2-1. General Information ST-series completes with stand –alone power inverter with AC transfer switch and is suitable f
2-3-4. Speed up transfer time and synchronized operation with the AC source at all times that allows the transfer to be interruption-free for sensit
2-4. Electrical Performance Specification Model No. Item ST1000-112 ST1000-124 ST1000-148 ST1000-212 ST1000-224 ST1000-248Continuous Output Power
2-4. Electrical Performance Specification Model No. Item ST1500-112 ST1500-124 ST1500-148 ST1500-212 ST1500-224 ST1500-248Continuous Output Power
2-4. Electrical Performance Specification Model No. Item ST2000-112 ST2000-124 ST2000-148 ST2000-212 ST2000-224 ST2000-248Continuous Output Power
2-4. Electrical Performance Specification Model No. Item ST2500-112 ST2500-124 ST2500-148 ST2500-212 ST2500-224 ST2500-248Continuous Output Power